Skip to content
Tuscan Foundry Products Logo Black
Find out more about our products by giving us a call
0333 987 4452
Linkedin Envelope
  • About Us
  • Buildings
    • Churches
    • Industrial
    • Residential
  • Finishes
  • Products
  • Support
  • Restoration Index
    • Conservation Rooflight Guide
  • Contact
  • News & Articles
  • About Us
  • Buildings
    • Churches
    • Industrial
    • Residential
  • Finishes
  • Products
  • Support
  • Restoration Index
    • Conservation Rooflight Guide
  • Contact
  • News & Articles
£0.00 0 Basket
Tuscan Foundry Products Logo Black
  • About Us
  • Buildings
    • Churches
    • Industrial
    • Residential
  • Finishes
  • Products
  • Support
  • Restoration Index
    • Conservation Rooflight Guide
  • Contact
  • News & Articles
  • About Us
  • Buildings
    • Churches
    • Industrial
    • Residential
  • Finishes
  • Products
  • Support
  • Restoration Index
    • Conservation Rooflight Guide
  • Contact
  • News & Articles
£0.00 0 Basket

Established 1893   |   BS 460:2002 Certified   |   UK & International Supply   |   Expert Technical Support   |   0333 987 4452

Bespoke Conservation Rooflights: The Specifier’s Guide to Purpose-Made Heritage Skylights and Period Roof Lights

  • October 16, 2026
Back
Bespoke and purpose-made conservation rooflights for listed buildings: made to measure, bespoke design, or copying an original cast iron rooflight.
A long, narrow purpose-made conservation rooflight with a single central glazing bar set flush into the stone slate roof of a Georgian country house.

When no standard size suits the rafters, the consent or the history of the building, the rooflight has to be made for the roof. This guide explains the three routes to a bespoke conservation rooflight (made to measure, bespoke design, and copying or repairing an original) and how to specify each one so that it is right first time.

In summary

A bespoke conservation rooflight is a purpose-made heritage roof light built to the dimensions, proportions and details of one particular roof, rather than chosen from a manufacturer’s standard size list. There are three routes. The first is a made-to-measure version of an established conservation pattern, sized to fit the existing rafters. The second is a bespoke design for an unusual shape, a linked run or a large opening. The third is a replica or repair of a surviving cast iron original. On a listed building, the right route is usually the one that removes the least historic fabric, which is why a bespoke unit so often beats a standard one. Agree position and size with the conservation officer first, survey the roof, and commission the unit against a signed approval drawing.

On this page

  • Introduction
  • What makes a rooflight "bespoke"?
  • When a standard conservation rooflight is not enough
  • The three routes to a bespoke heritage rooflight
  • Specifying a purpose-made period rooflight: the details that matter
  • Commissioning a bespoke conservation rooflight, step by step
  • Costs and lead times for bespoke rooflights
  • Common mistakes with bespoke rooflights
  • Historic buildings where bespoke rooflight decisions mattered
  • Frequently asked questions
  • Conclusion

Introduction

Most conservation rooflights are bought from a standard size list, and for many buildings that is exactly right. The difficulty is that historic roofs were not built to a module. Rafters wander, pitches vary across one slope, and the opening an architect needs rarely lines up with the size a catalogue offers.

A bespoke conservation rooflight solves that by making the rooflight fit the building, rather than altering the building to fit the rooflight. It may be a standard conservation pattern built to a non-standard size, a purpose-made design for a run of linked lights or an unusual shape, or a faithful copy of a Victorian cast iron rooflight that has finally corroded beyond use.

This guide is written for conservation architects, surveyors, conservation officers and heritage contractors. It sits within our wider Conservation Rooflight Guide, and it deliberately goes further than the short “standard or bespoke” section in our guide to ordering conservation rooflights. Here we look at what bespoke actually means, when it is justified, how each route differs, and where most purpose-made rooflight projects go wrong.

We should be clear about our own position. We do not manufacture new rooflights. We are cast iron specialists, supplying heritage rainwater goods since 1893, and we copy-cast missing or damaged castings, survey historic roofs, and supply rooflight winders and openers. That gives us a particular interest in the oldest bespoke route of all: keeping the original cast iron rooflight in the roof.

What makes a rooflight "bespoke"?

A rooflight is bespoke when at least one of its defining features (size, proportion, shape, profile, glazing division, material or finish) is made for a specific roof rather than taken from a standard range. The market uses several overlapping terms, and it pays to know which one a supplier means.

TermWhat it usually meansWhat to ask
Made to measureA standard conservation pattern built to non-standard width or lengthWhich dimensions can change, and in what increments?
Bespoke designA purpose-designed unit: linked runs, trapezoidal, large, escape or flat-roof heritage unitsWho produces the drawings, and is the design tested?
Purpose-madeBuilt for one opening; often used of both of the aboveIs it a one-off or a modified stock unit?
Replica or copyA new rooflight reproducing a surviving originalIs it copied from the original, or “in the style of”?
Period or heritage rooflightA descriptive term for appearance, not a standardProjection, frame section and glazing bar construction
Conservation-styleOften a modern frame with heritage stylingIs the frame steel or cast iron, and is the bar structural?

Rooflight, skylight and roof window describe the same element, so a bespoke conservation skylight and a bespoke heritage roof light are the same commission under different names. The term that matters is not on the box. It is the frame section, the projection above the slope and whether the glazing bar is a genuine structural member. Those are covered in detail in our specification guide for conservation rooflights.

When a standard conservation rooflight is not enough

A bespoke rooflight is justified when a standard size would mean cutting historic timbers, breaching a consent condition, or producing a unit that looks wrong on the building. These are the situations we see most often.

  • The rafters are original and irregular. Trimming a historic rafter to suit a stock size is a structural alteration and a loss of fabric. A unit sized to the existing gap avoids both.
  • An existing opening is being re-used. Replacing a rooflight in its original opening is far easier to justify than forming a new one, but the old opening is almost never a current stock size.
  • The consent fixes the dimensions. Conservation officers increasingly specify exact sizes, the glazing bar, the finish and sometimes the manufacturer. A standard unit that is “nearly right” is a breach.
  • Proportion is part of the significance. A rooflight that matches the proportion of the windows below, or of a surviving historic rooflight elsewhere on the roof, reads as part of the building rather than as an addition.
  • The roof needs a run of lights. Industrial buildings, barns and studios often need several units in a regular rhythm, with mullions that line up with retained rafters.
  • The shape is unusual. Hipped and conical roofs, lanterns, railway and industrial buildings, and steep or shallow pitches at the edge of a standard range all need purpose-made solutions.
  • An original survives. Where a Victorian cast iron rooflight is still in place, the first question is not which replacement to buy, but whether it can be repaired.

The three routes to a bespoke heritage rooflight

Every bespoke conservation rooflight follows one of three routes, and each has a different cost, programme and consent profile. Choosing the route is the first specification decision, and it should be made before any product is selected.

RouteBest forMain advantageMain limitation
1. Made to measureIrregular rafters, re-used openings, fixed consent sizesTested conservation pattern, sized to the roofProportion and detail stay within the maker’s range
2. Bespoke designLinked runs, unusual shapes, large or special unitsSolves problems no standard range canLonger lead time; design and drawing approval stages
3. Copy or repair of an originalSurviving cast iron rooflightsKeeps or reproduces historic fabric and detailDepends on condition; needs specialist assessment

Route 1: made-to-measure conservation rooflights

Made to measure is the most common form of bespoke rooflight: an established conservation pattern built to the size the roof needs. The leading specialist makers offer it alongside their standard ranges. The Rooflight Co. publishes a set of classic sizes plus a made-to-measure service intended to avoid cutting existing rafters, and Clement offers bespoke sizes on request in addition to its standard slate and tile profiles.

The benefit is that you keep the tested frame, glazing and flashing system while gaining the exact size. The limitation is that you are still buying that maker’s pattern, so details such as the frame section, the glazing bar and the hinge arrangement are not open to change. For most listed houses, barns and terraces, that is exactly what is needed. We list both makers in the rooflights category of our Building Restoration Index, and enquiries go to them directly.

Route 2: bespoke-design heritage rooflights

A bespoke design is a purpose-made rooflight for a problem that no standard range solves: a linked run, an unusual shape, a very large opening, or a special glazing, escape or ventilation requirement. This is the route for mills, railway buildings, chapels, studios and complex roofs.

Typical commissions include linked runs set to the rhythm of the window bays below, trapezoidal or tapering units for hipped and conical roofs, heritage lanterns, and top-hung escape units where the standard range only offers side-hung. Each needs drawings, structural input where rafters are trimmed, and a flashing kit designed for the whole assembly rather than improvised on site.

A long linked run of purpose-made heritage rooflights set flush into the slate roof of a converted nineteenth-century stone textile mill.
A run of purpose-made linked rooflights set to the rhythm of the window bays on a converted stone mill. Illustrative image.

Large bespoke units are heavy, mostly because of the glass, and conservation officers tend to resist single large openings in traditional roofs. Several modest units in a regular rhythm usually keep more of the roof plane intact and read more like a historic pattern of lights. Our guide to choosing a heritage rooflight compares frame materials and sightlines across the market.

Route 3: copying or repairing an original cast iron rooflight

Where a Victorian cast iron rooflight survives, repair is usually the preferred conservation outcome, and a faithful copy is the next best. Every modern conservation rooflight is an imitation of these originals; the original itself is the most authentic period roof light a building can have.

Many originals can be repaired. Corrosion can be cleaned back, the glass and putty renewed, the stay or hinge refurbished, and the frame primed and painted with a linseed oil paint system that suits historic ironwork. Where a casting is cracked or missing, a matching piece can be copy cast from the surviving original or from a sound example elsewhere on the building.

An original Victorian cast iron rooflight with flaking paint and surface corrosion in a Welsh slate roof, awaiting assessment for repair.
A surviving Victorian cast iron rooflight with flaking paint and surface corrosion: the first question is whether it can be repaired. Illustrative image.

Copy casting starts from reference material: the original casting or a fragment of it, measured drawings, or good photographs with dimensions. A pattern is made, a mould is formed in sand, and the new casting reproduces the profile, the raised rim and the cast glazing bar of the original. We discuss the process on our bespoke and copy casting page. Our typical lead time for bespoke and copy-cast work is 8 to 10 weeks from pattern approval, and we flag that at the outset so it can be programmed.

A worn original cast iron rooflight frame beside a timber foundry pattern and a new raw cast iron copy on a workbench.
An original cast iron frame, a timber pattern made from it, and a new sand-cast copy. Illustrative image of the copy casting sequence.

There are honest limits. Single glazing in an original frame will not meet current thermal targets, although Approved Document L allows relaxation for listed buildings where compliance would harm character, provided the work gets as close to the target as the building safely allows. Some owners keep the original and add discreet secondary glazing beneath it, a detail with genuine Victorian precedent. Where the frame has corroded through, particularly in coastal locations, replacement with a purpose-made unit matching the original proportions and glazing division is often the sounder decision. A site survey can assess the rooflights and the rainwater goods together before anything is ordered.

Specifying a purpose-made period rooflight: the details that matter

A bespoke rooflight is only as good as its specification, and the details that decide it are the frame, the profile, the glazing bar, the glazing, the lining, the finish and the opening. Most of these are covered in depth in our specification guide; here are the points that matter most when a unit is being made to order.

DetailWhat to specify on a bespoke unitWhy it matters
Frame materialSteel (zinc-treated and coated), stainless steel in exposed or coastal sites, or cast iron for copiesSection size, durability and authenticity
ProfileMatched to the actual covering: slate, plain tile, pantile, stone slateDecides whether the unit sits flush
Glazing barStructural, in the frame material, positioned as the original or the consent requiresApplied bars cast shadows and are routinely rejected
GlazingSlim sealed unit, laminated inner pane for overhead glazing; check thickness against flush fitThick units push the frame proud of the roof
LiningTimber lining sitting flush to the revealThe internal face is seen every day
FinishBlack or the colour the consent requires; coating system to suit exposureCoated steel lasts as long as its coating
OpeningFixed, top-hung with winder, or escape; opening angle checked against Approved Document FRestricted angles can fail purge ventilation

Two points deserve emphasis. First, ask in writing whether the glazing bar is structural, because conservation officers no longer accept a strip applied to the glass as a substitute. Second, check the opening angle of the mechanism actually being supplied. We stock brass and chrome hand and pole winders in our rooflight and window openers range, but the angle a winder achieves is a ventilation calculation, not a detail.

A long, narrow purpose-made conservation rooflight with a single central glazing bar set flush into the stone slate roof of a Georgian country house.
A long, narrow purpose-made rooflight set into a stone slate roof above a cast iron ogee gutter. Illustrative image.

Commissioning a bespoke conservation rooflight, step by step

The commissioning sequence for a bespoke rooflight is survey, consent, drawing, approval, manufacture and installation, and the order matters. Ordering before consent is settled is the most expensive mistake in this field.

  1. Survey the roof. Measure each rafter bay at top, middle and bottom, the pitch on the rafter, the covering and its gauge, and the internal head and sill heights. Record any surviving historic rooflights and their condition.
  2. Agree position and size first. Take pre-application advice from the conservation officer on the slope, the number and the proportion of units before choosing a maker.
  3. Prepare consent drawings. Show the rooflight in elevation and section, its relationship to the slate or tile courses, and the glazing bar. Our permissions guide explains the regime in each UK nation.
  4. Discharge the conditions. Do not order a bespoke unit until conditions on size, bar or finish are discharged.
  5. Check the approval drawing line by line. Sizes, profile, pitch, glazing, bar, opening, winder, colour, coating, lining and flashing kit. Send it to the architect or officer if the consent specifies details.
  6. Programme manufacture against the scaffold. Bespoke units carry longer lead times, set by the maker at quotation. Scaffold is hired by the week.
  7. Install with the roof works. Flashings, insulation to the frame and the vapour control layer, then lining and making good, as set out in our installation guide.

While the scaffold is up, inspect the cast iron gutters and downpipes below. A rooflight concentrates water at its head and sides, and the rainwater goods on that elevation are cheapest to put right in the same programme.

Costs and lead times for bespoke rooflights

A bespoke conservation rooflight is quoted individually, and it usually costs more than a stock unit of similar size, though the unit is rarely the largest cost of the job. Scaffold, structural work, leadwork, lining and making good often exceed it.

Lead times are set by each maker and usually run from the signed approval drawing, so ask for the figure in writing at quotation and again at approval. For our own work, bespoke and copy-cast castings typically take 8 to 10 weeks from pattern approval. Where a project combines new rooflights with replacement rainwater heads or gutters, order both at the start of the programme so that neither holds up the scaffold.

The cost argument for bespoke is often stronger than it looks. A unit sized to the existing rafters can avoid trimming, structural engineering and the consent difficulties of removing historic timber. A repaired original may cost less than any replacement and keeps the building’s own fabric.

Common mistakes with bespoke rooflights

  • Choosing the product before the position. The conservation case is made on the slope and the size, not the brand.
  • Calling a “conservation-style” frame bespoke. A deep modern frame with heritage styling, built to a special size, is still a deep modern frame.
  • Replacing a repairable original. Expect the officer to ask why the historic rooflight cannot be kept.
  • Ordering before consent conditions are discharged. Changing a bespoke order is expensive and slow.
  • Sizing an escape unit by its external frame. Approved Document B requires 0.33 m² of clear opening, at least 450 mm in each direction.
  • Improvising flashings on linked runs. A run needs one flashing kit designed for the whole assembly.
  • Ignoring the coating on exposed sites. Coastal salt attacks steel at edges and fixings; discuss exposure with the maker before ordering.
  • Forgetting the water. The rainwater calculation should be revisited whenever a new opening is formed.

Historic buildings where bespoke rooflight decisions mattered

These are published examples drawn from planning records and award citations. None is a Tuscan Foundry project.

The Old Manse, Helmsdale, Sutherland: Category B

A two-storey harled house of about 1845 with a slated roof, The Old Manse had two traditional cast iron rooflights, almost flush with the roof, alongside two later modern units that stood proud of the slope. On appeal in 2016, the Reporter found the cast iron rooflights badly corroded and beyond repair, and granted listed building consent on condition that both replacements were conservation type, rejecting a standard modern unit on the less visible slope. The decision is a clear statement that low visibility does not justify losing the character of the roof.

Ashvale, St Martin's, Isles of Scilly: Grade II

Ashvale is a mid-nineteenth-century granite farmhouse with an adjoining workshop under a pantile roof. Its two cast iron rooflights had rusted through in salt-laden air, could no longer be opened, and were shedding pieces of frame. Listed building consent was granted in 2025 for purpose-made marine-grade stainless steel replacements, finished black, set flush in the roof and reproducing the original three-light configuration. It is a textbook example of a bespoke replica: new material for a hostile environment, original proportion and division retained.

15–17 York Street, Clitheroe, Lancashire: Grade II

This pair of late eighteenth or early nineteenth-century townhouses forms part of a listed terrace. A 2016 re-roofing application proposed replacing a corroded rooflight over the second-floor landing of number 17 with a conservation rooflight to match the existing, and reinstating a matching rooflight over number 15, where one is thought to have been removed during earlier re-slating. Both were positioned on the rear slope, out of sight, to light the stair and allow later restoration of an internal ceiling lantern.

Artemis Barn, Castleton, Derbyshire: Peak District National Park

A 250-year-old stone barn in the Peak District National Park, converted by Chiles Evans + Care Architects into a family home. Planning officers guided each element of the work, and the architect specified linked Conservation Rooflights from The Rooflight Co., which were approved for the scheme. The linked run lights a triple-height living space while keeping the barn’s modest external character. The project won a RIBA East Midlands Award and the RIBA East Midlands Conservation Award in 2017.

The Roundhouse, Derby: listed railway building

The early Victorian railway roundhouse in Derby, now part of Derby College, shows the bespoke-design route at scale. The reconstruction of its roof called for 48 bespoke trapezoidal rooflights, made by The Rooflight Co. to suit the radiating geometry of the structure, alongside 63 further rooflights from the maker’s Studio range. No standard size list could have served a roof of that shape; purpose-made units let the building keep its daylit, industrial character.

Frequently asked questions

What is the difference between a bespoke conservation rooflight and a standard one?

A standard conservation rooflight comes from a manufacturer’s fixed size list, while a bespoke one is made for a particular roof: built to a non-standard size, designed for an unusual shape or linked run, or copied from a surviving original. The appearance can be identical. The difference is that a bespoke unit fits the existing rafters, opening and consent rather than requiring the roof to be altered to suit the product.

Do I need listed building consent for a bespoke rooflight on a listed building?

Almost always, yes. Forming a new opening, altering an existing one or replacing a historic rooflight with a different design affects the character of a listed building, and consent applies at every grade. Like-for-like repair of an original may not need consent, but only the local planning authority can confirm that, so get the answer in writing before any work starts.

Can an original Victorian cast iron rooflight be repaired rather than replaced?

Often it can. Corrosion can be cleaned back, the glass and putty renewed, the stay refurbished and the frame repainted, and a cracked or missing casting can be copy cast from the original. Repair is usually the preferred route on a listed building. Replacement becomes the sounder decision when the frame has corroded through or cracked beyond reliable repair, as often happens in coastal locations.

How long does it take to make a bespoke conservation rooflight?

Lead times for new bespoke rooflights are set by each manufacturer at quotation and usually run from the signed approval drawing, so ask for the figure in writing before booking scaffold. Standard sizes can arrive within days. For copy-cast cast iron components, our typical lead time is 8 to 10 weeks from pattern approval.

Is a bespoke heritage rooflight more expensive than a standard one?

The unit usually costs more, but the job may not. A rooflight sized to the existing rafters can avoid trimming timbers, engineering input and the consent difficulty of removing historic fabric. Scaffold, leadwork, lining and making good are often the larger costs, which is why it pays to plan rooflight and rainwater work in the same scaffold programme.

Can bespoke rooflights be linked together in a run?

Yes. Linked runs are one of the most common bespoke commissions, particularly on barns, mills and studios. Several smaller units in adjacent rafter bays usually find more favour with conservation officers than one large opening. Agree the mullion width, which units open, and a single flashing kit designed for the whole run before ordering.

What should I send to get a quotation for a purpose-made period rooflight?

Send the rafter measurements at top, middle and bottom of each bay, the roof pitch, the covering type, internal head and sill heights, photographs inside and out, and any consent drawings and conditions. If an original rooflight survives, include close photographs and dimensions of it. The more complete the survey, the faster and more accurate the quotation.

Conclusion

A bespoke conservation rooflight is not a luxury. On a historic roof it is often the option that does least harm: it fits the existing rafters, re-uses the existing opening, honours the proportions of the building and, where an original survives, keeps the building’s own fabric in place. Choose the route first, made to measure, bespoke design or copy and repair, then settle position and size with the conservation officer, survey the roof properly, and commission against a signed approval drawing. Ask whether the glazing bar is structural, check the opening angle against the ventilation requirement, and draw the water.

At Tuscan Foundry Products, we have worked with cast iron on historic buildings since 1893. We do not make new rooflights, and for those we point specifiers to specialist makers such as The Rooflight Co. and Clement Windows Group. Where we help is with the cast iron: advising on whether an original rooflight can be repaired, copy casting missing or broken castings (typically 8 to 10 weeks from pattern approval), supplying winders and openers, and supplying the cast iron rainwater goods that sit beneath every rooflight, with an in-house linseed oil finish. For complex roofs, our chargeable site survey looks at the rooflights and the rainwater system together before anything is ordered. Call us on 0333 987 4452 or contact our team to discuss your project.

Facebook
Twitter
LinkedIn
Pinterest
PrevPrevious
Tuscan Foundry Products Logo White

CONTACT US

Sales & Customer Services:
0333 987 4452

Tyn-Y-Clyn
Llanafan Fawr
Builth Wells
Powys LD2 3LU
United Kingdom

FOLLOW US

Twitter

MESSAGE US

ABOUT US
  • About Us
  • News
  • Testimonials
  • Gallery
  • About Us
  • News
  • Testimonials
  • Gallery
PRODUCTS
  • Bespoke Commissions
  • Cast Iron Soil Pipes
  • Cast Iron Gutters & Pipes
  • Heating & Cast Iron Radiators
  • Hardware & Spares
  • Cast Iron Radius Guttering
  • Bespoke Commissions
  • Cast Iron Soil Pipes
  • Cast Iron Gutters & Pipes
  • Heating & Cast Iron Radiators
  • Hardware & Spares
  • Cast Iron Radius Guttering
SUPPORT
  • Brochures
  • Delivery
  • International Shipping
  • Downloads
  • Surveys & Visits
  • Rooflight Guide
  • Brochures
  • Delivery
  • International Shipping
  • Downloads
  • Surveys & Visits
  • Rooflight Guide
CONTACT
  • Contact
  • Referral Scheme
  • FAQ
  • Privacy Policy
  • Terms And Conditions
  • Contact
  • Referral Scheme
  • FAQ
  • Privacy Policy
  • Terms And Conditions
Tuscan Foundry Products Logo Black
Find out more about our products by giving us a call
0333 987 4452

Tuscan Foundry Products, Tyn-Y-Clyn, Llanafan Fawr, Builth Wells, Powys LD2 3LU, United Kingdom

© Tuscan Foundry Products 2026

This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish.AcceptReject Read More
Privacy & Cookies Policy

Privacy Overview

This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary
Always Enabled
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Non-necessary
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.
SAVE & ACCEPT