Victorian 4 Column Cast Iron Radiator – 353mm, Primed
£111.00 – £1,110.00Price range: £111.00 through £1,110.00 ex VAT (£133.20 – £1,332.00 inc VAT)
Victorian 4 column cast iron radiator, 353mm high, supplied in primer for painting on site. 40.8W per section at ΔT50, 140mm deep, 3 to 30 sections. Priced per radiator by number of sections.
The Victorian 4 column is the classic British cast iron radiator: square-edged columns, a plain face and a profile true to radiators fitted in houses, schools and institutions from the 1880s onwards. At 353mm high it suits low window sills, bay windows and beneath window seats, where most radiators are too tall. It is supplied in primer, ready to be painted on site, so the decorator can match the room’s joinery or a historic colour scheme in the same paint system. Primer is the usual choice on conservation projects, and lead time is typically 14 days.
Each section is 50mm wide and 140mm deep, and gives 40.8W at ΔT50 (tested to BS EN 442). On a heat pump at ΔT30 that falls to about 21.0W per section, so size the radiator at the temperature your system will actually run at. Radiators are rated to 6 bar working pressure, have ½” BSP connections and carry a 10-year guarantee.
Specification
| Height | 353mm floor-standing on integrated feet (288mm wall-hung) |
|---|---|
| Depth | 140mm (172mm or 182mm wall to face, depending on brackets) |
| Section width | 50mm, plus 24mm overall for the end bushes |
| Output per section | 40.8W at ΔT50 · about 21.0W at ΔT30 |
| Dry weight | 2.58kg per section |
| Sections | 3 to 30; factory built and pressure tested up to 20, longer radiators joined on site |
| Finish | Primer, for painting on site |
| Connections and pressure | ½” BSP · 6 bar working pressure (7.8 bar test) |
| Guarantee | 10 years against manufacturing defects |
Sizes at a glance
| Sections | Length | Output ΔT50 | Output ΔT30 | Price ex VAT |
|---|---|---|---|---|
| 6 | 324mm | 245W | 126W | £222.00 |
| 10 | 524mm | 408W | 210W | £370.00 |
| 14 | 724mm | 571W | 294W | £518.00 |
| 20 | 1,024mm | 816W | 420W | £740.00 |
Length is the number of sections × 50mm + 24mm. Sections are sand cast, so allow ±2mm per section and set valve tails once the radiator has arrived. Valves are sold separately: our Kentwell, Belgrave and Clarendon valve sets suit this radiator.
Choosing and sizing
The 353mm height is usually chosen for Georgian and Regency rooms with low sills, bay windows and window seats. To size it, divide the room’s heat loss by the output per section and round up. Our guide to sizing cast iron radiators for a period room and our guide to cast iron radiators with heat pumps work through examples, and the 2026 specification guide (PDF) lists every height and output. The same radiator is also available factory painted. See the whole Victorian radiator range or the radiators in period rooms in our radiator gallery.
The Victorian 4 column is the plain pattern conservation officers usually prefer in listed buildings. Send us your room heat losses and we will prepare a radiator schedule with section counts and lengths at boiler and heat pump temperatures. Call 0333 987 4452 or contact us.
Images are illustrative. The section count and finish shown may differ from your order.
Additional information
| Sections | 3 Sections, 4 Sections, 5 Sections, 6 Sections, 7 Sections, 8 Sections, 9 Sections, 10 Sections, 11 Sections, 12 Sections, 13 Sections, 14 Sections, 15 Sections, 16 Sections, 17 Sections, 18 Sections, 19 Sections, 20 Sections, 21 Sections, 22 Sections, 23 Sections, 24 Sections, 25 Sections, 26 Sections, 27 Sections, 28 Sections, 29 Sections, 30 Sections |
|---|
What is the output of the 353mm Victorian 4 column cast iron radiator?
How long is a 353mm Victorian 4 column radiator?
Is a Victorian 4 column cast iron radiator suitable for a listed building?
Can I use the 353mm Victorian 4 column radiator with a heat pump?
How much does a 353mm Victorian 4 column radiator cost?
Technical data sheet
Every product in our cast iron radiator range has a double-sided A4 technical data sheet, written for architects, specifiers and heating engineers. It includes dimensioned drawings, outputs at ΔT50 and ΔT30, weights, water content, fixing details and a model specification clause you can copy into your specification.
Send us your room heat losses and we will prepare a radiator schedule for your project. Call 0333 987 4452.
Related products
-
Victorian 4 Column Cast Iron Radiator – 935mm, Painted
£300.60 – £3,006.00Price range: £300.60 through £3,006.00 ex VAT (£360.72 – £3,607.20 inc VAT) Select options This product has multiple variants. The options may be chosen on the product page -
Victorian 4 Column Cast Iron Radiator – 785mm, Primed
£207.90 – £2,079.00Price range: £207.90 through £2,079.00 ex VAT (£249.48 – £2,494.80 inc VAT) Select options This product has multiple variants. The options may be chosen on the product page -
Victorian 4 Column Cast Iron Radiator – 636mm, Primed
£162.30 – £1,623.00Price range: £162.30 through £1,623.00 ex VAT (£194.76 – £1,947.60 inc VAT) Select options This product has multiple variants. The options may be chosen on the product page